123-354 Decrease In 24V Error (Ui-Panel) Rap; 123-355 Decrease In 5V Error (Ui-Panel) Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

123-354 Decrease in 24V Error (UI-Panel) RAP

BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
24V Power Drop Detected error (UI-Panel). The Control Panel has detected a drop in 24V
power voltage.
Procedure
Turn the power OFF then ON, and then replace the One-Touch Key Module of the MCW-
Panel.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace UI I/F PWB
(PL
1.7)
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
Status Indicator RAPs
123-354, 123-355

123-355 Decrease in 5V Error (UI-Panel) RAP

BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
. 5V Power Drop Detected error (UI-Panel). The Control Panel has detected a drop in 5V
power voltage.
Procedure
Turn the power OFF then ON, and then replace the One-Touch Key Module of the MCW-
Panel.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace UI I/F PWB
Replace ESS PWB