034-711 Waiting for Link Timeout RAP

BSD-ON:
BSD 34.1 - FAX
Fax controller is waiting for a data link time-out.
Procedure
Check the Fax line connection (telephone line).
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the PWBs in the FAX Module
Check the sw version of the fax & controller sw - update if required
Perform FAX Diagnostic
GP 13
Replace the FAX PWB
(PL
18.5).
Initial Issue
WorkCentre 5335 Family Service Documentation

034-712 Internal Error (Interrupt) RAP

BSD-ON:
BSD 34.1 - FAX
There is an internal processing error.
Procedure
Check the remote machine settings and line status, then perform the operation again.
Check the Fax line connection (telephone line).
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the PWBs in the FAX Module
Check the sw version of the fax & controller sw - update if required
Perform FAX Diagnostic
Replace the FAX PWB
07/2011
2-603
BUS Updated 12/2011
GP 13
(PL
18.5).