116-314 Ethernet Address RAP
An Ethernet address error is detected.
Initial Actions
Power Off/On
Procedure
•
Check the EEPROM on the ESS.
•
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
•
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
–
SNTP
–
NetWare
–
Salutation IO
–
SMB
–
Port 9100
–
USB
–
lpd
–
FTP Serv
–
MailIO
–
IPP
–
Check the sw version of the controller sw - update if required
–
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs
116-314, 116-315
116-315 System Memory DIMM R/W Check RAP
An error is detected during the Read/Write operation of the System Memory DIMM.
Initial Actions
Power Off/On
Procedure
•
Pull out and insert the System Memory DIMM.
•
Check the sw version of the controller sw - update if required
•
If the problem persists, replace the System Memory DIMM
•
If the problem persists, replace the ESS PWB
07/2011
2-850
BUS Updated 12/2011
(PL
35.2).
(PL
35.2).
Initial Issue
WorkCentre 5335 Family Service Documentation