123-345 Timer Queue Full Rap; 123-346 Invalid Timer Number Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

123-345 Timer Queue Full RAP

BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
The UI software failed an event timer.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace UI I/F PWB
(PL
1.7)
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
Status Indicator RAPs
123-345, 123-346

123-346 Invalid Timer Number RAP

BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
The UI software failed a timer routine.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace UI I/F PWB
Replace ESS PWB
07/2011
2-936
BUS Updated 12/2011
(PL
1.7)
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
WorkCentre 5335 Family Service Documentation