116-361 Spool HDD RAP
The controller spool detected an error during HDD access.
Initial Actions
Power Off/On
Procedure
•
Check the HDD electrical connections
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
Hard Disk Failure Prediction
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs
116-361, 116-362
(PL
35.2).
Test.
BUS Updated 12/2011
116-362 SSDP Software RAP
An internal shutdown occurred after an SSDP (Simple Service Discovery Protocol) processing
error.
Initial Actions
Power Off/On
Procedure
•
Check the HDD electrical connections
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
07/2011
2-870
(PL
35.2).
Hard Disk Failure Prediction
Test.
WorkCentre 5335 Family Service Documentation
Initial Issue