121-337 Accessory Self Diag Fail RAP
BSD-ON:
BSD 3.7 - ESS-FDI Communication
System Fail. Accessories self-diagnostic result error. Self-diagnostic of the accessories in
WAKE UP ANSWER resulted in an error.
Procedure
1.
Check connection of the cable between the FDI and the ESS.
2.
If they are connected correctly, turn the power OFF then ON. If the problem persists, per-
form the following procedure to repair it.
3.
Check the sw version of the controller sw - update if required
4.
Replace the FDI.
5.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
6.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
7.
Replace RAM DIMM on ESS PWB
(PL
8.
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)
Status Indicator RAPs
121-337, 121-338
35.2)
BUS Updated 12/2011
121-338 FDI Answer Time Out RAP
BSD-ON:
BSD 3.7 - ESS-FDI Communication
System Fail. FDI - Answer Timeout. Answers other than WAKE UP ANSWER from the FDI
cannot be received.
Procedure
1.
Check connection of the cable between the FDI and the ESS.
2.
If they are connected correctly, turn the power OFF then ON. If the problem persists, per-
form the following procedure to repair it.
3.
Check the sw version of the controller sw - update if required
4.
Replace the FDI.
5.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
6.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
7.
Replace RAM DIMM on ESS PWB
8.
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM)
07/2011
2-922
(PL
35.2)
WorkCentre 5335 Family Service Documentation
Initial Issue