024-367 Decompression Synchronization RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Incorrect line synchronization was detected.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Uninstall and reinstall the Page Memory
•
If the problem persists, replace the Page Memory
•
Check that connectors on the HDD, MCU PWB
are securely connected. Disconnect then reconnect the ESS, MCU all PWBs connected
to them (RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs
024-367, 024-368
(PL
35.2)
(PL
35.2).
(PL
18.2) and on the ESS PWB
(PL
35.2)
BUS Updated 12/2011
024-368 PCI RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
PCI access error occurred due to a faulty PCI bus.
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Uninstall and reinstall the Page Memory
•
If the problem persists, replace the Page Memory
•
Check that connectors on the HDD, MCU PWB
are securely connected. Disconnect then reconnect the ESS, MCU all PWBs connected
to them (RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
35.2)
•
Replace RAM DIMM on ESS PWB
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
07/2011
2-390
(PL
35.2)
(PL
35.2).
(PL
18.2) and on the ESS PWB
(PL
35.2)
WorkCentre 5335 Family Service Documentation
(PL
35.2)
Initial Issue