IQS10 Resolution Specification
Procedure
Use Side B of the Standard Test Pattern.
The complete resolution of designated LP/mm lines for specific magnification percentages is
listed in Table below.
It is also required that the designated LP/mm lines be resolved in the top-to-bottom direction
and the side-to-side direction over the entire copy
Initial Issue
WorkCentre 5335 Family Service Documentation
(Figure
1).
BUS Updated 12/2011
Table 1 Resolution Specifications
Magnification(%)
Resolution LP/mm
70
2.5
100
4.3
141
3.5
200
3.5
07/2011
3-25
Figure 1 Resolution
Image Quality