202-399 Internal Timer RAP
An internal error was detected in the machine timer.
The setting value of SystemData=700-124 (Auto Clear Timer (Auto Resume Timer,
Auditron Off Timer, Tools Off Timer) is detected to be 1~29 in MF machines.
Procedure
•
Turn the power OFF then ON.
•
Check the value of SystemData=700-124 (Auto Clear Timer (Auto Resume Timer, Audi-
toron Off Timer, Tools Off Timer).
•
If the value of 1~29 is set in an MF machine, a Fail will occur.
•
If this Fail occurs when timer related System Data Settings Value for other than 700-124
is changed, check the normal values for the related System Data.
•
If the problem persists, perform the following procedure to repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
Dimm)