IQ7 Deletion RAP
Part of the image is missing.
Procedure
Check the paper type. Paper used is within specifications.
Y
N
Use paper within specifications.
Use paper from a freshly opened packet. The problem reoccurs.
Y
N
End
Remove the Xerographic Cartridge and reinstall. Turn the power Off/On and print. The prob-
lem reoccurs.
Y
N
End
Install a new Xerographic Cartridge
(PL
8.1). Turn the power Off/On and print. The
reoccurs.
Y
N
End
Check the surface of the BTR for distortion. There is no distortion on the surface of the
BTR.
Y
N
Replace the BTR
(PL
6.1).
Replace the MCU PWB
(PL
18.2). If the problem persists, replace the ESS PWB
Image Quality
IQ7, IQ8
IQ8 Skew/Misregistration RAP
Printed images are not parallel to the edges of the paper.
Procedure
Check the location where the machine is installed. The machine is installed on a stable hor-
izontal surface.
Y
N
Install the machine on a stable horizontal surface.
Remove the Xerographic Cartridge
The problem reoccurs.
Y
N
End
Check the installation of the Paper Cassette. The Paper Cassette is correctly installed.
Y
N
Install the Paper Cassette correctly.
problem
Check for distortion in the paper delivery path. There is no distortion in the paper delivery
path.
Y
N
Correct the distortion or replace the distorted part.
Replace the MCU PWB
(PL
35.2).
07/2011
3-6
BUS Updated 12/2011
(PL
8.1) and reinstall. Turn the power Off/On and print.
(PL
18.2). If the problem persists, replace the ESS PWB
WorkCentre 5335 Family Service Documentation
(PL
35.2).
Initial Issue