123-207 Communication Manager Target RAP
BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
A mailbox operations value is incorrect.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace UI I/F PWB
(PL
1.7)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)
Initial Issue
WorkCentre 5335 Family Service Documentation
123-209 Controller UI Communication RAP
BSD-ON:
BSD 2.1 - User Interface (UI)
BSD-ON:
BSD 3.4 - ESS - UI Communication
An incorrect check value is received during Controller UI Communications.
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, UI I/F, ESS, MCU all PWBs connected to them (RAM,
Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace UI I/F PWB
•
Replace ESS PWB
07/2011
2-925
BUS Updated 12/2011
(PL
1.7)
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB.)