042-323 Drum K Motor Drive Failure RAP
BSD-ON:4.1
The Drum Motor is not rotating at the specified speed.
Initial Actions
•
Power OFF/ON
•
Reload the Xero/Developer Cartridge
Procedure
Close the LH Cover and the Front Cover.
Execute
Component
Control[071-037 Drum Motor ON]. The Drum Motor can be heard.
Y
N
Go to the
OF 3
(MAIN DRIVE ASSY RAP).
Check the installation of the Main Drive Assembly
1.1) is installed correctly.
Y
N
Install the Main Drive Assembly
(PL
Check the wire between J408-7 and J214-8 for an open circuit or a short circuit (BSD 4.1
7). The wire between J408-7 and J214-8 is conducting without an open circuit or a short
circuit.
Y
N
Repair the open circuit or short circuit.
Manually rotate the Main Motor rotor. It rotates smoothly.
Y
N
Check for foreign substances that are interfering with operation or installation failure.
Foreign substances or installation failure are found.
Y
N
Replace the Main Drive Assembly
Remove the foreign substances that are interfering with operation and correct the installa-
tion failure.
Replace the Main Drive Assembly
(PL
1.1). If the problem persists, replace the MCU PWB
9.1).
Launch Version
WorkCentre 5225, 5230
(PL
4.1) and the Fuser Unit
(PL
5.1).
(PL
1.1). The Main Drive Assembly
1.1) correctly.
(PL
1.1).
042-325 Main Motor Failure RAP
BSD-ON:4.1
The Main Motor is not rotating at the specified speed.
Initial Actions
•
Power OFF/ON
•
Reload the Xero/Developer Cartridge
Procedure
Close the LH Cover and the Front Cover.
Execute
Component Control
[042-001 Main Motor ON]. The Main Motor can be heard.
Y
N
Go to the
OF 3
(MAIN DRIVE ASSY RAP).
Check the installation of the Main Drive Assembly
(PL
installed correctly.
Y
N
Install the Main Drive Assembly correctly.
Check the wire between J410 and J214 for an open circuit or a short circuit (BSD 4.1B). The
Flag
wires are conducting without an open circuit or a short circuit.
Y
N
Repair the open circuit or short circuit.
Manually rotate the Main Motor rotor. It rotates smoothly.
Y
N
Check for foreign substances that are interfering with operation or installation failure.
Foreign substances or installation failure are found.
Y
N
Replace the Main Drive Assembly
Remove the foreign substances that are interfering with operation and correct the installa-
tion failure.
Replace the Main Drive Assembly
9.1).
(PL
February, 2008
2-501
(PL
4.1) and the Fuser Unit
(PL
(PL
1.1). The Main Drive Assembly is
(PL
1.1).
(PL
1.1) If the problem persists, replace the MCU PWB
Status Indicator Raps
042-323, 042-325
5.1).
(PL