Figure 2 IIT PWB Connectors
4.
Remove the IIT PWB
(Figure
3)
(1) Remove the screws (x6).
(2) Remove the IIT PWB.
Figure 3 IIT PWB Removal
Replacement
1.
To install, carry out the removed steps in reverse order.
2.
When the PWB is replaced, remove the EEPROM from the old PWB and install it onto the
new one
(Figure
4), refer to Downloading Software
Repairs & Adjustments
REP 6.10
GP
16.
07/2011
4-50
BUS Updated 12/2011
Figure 4 EEPROM