024-374 Registration Con Pll Parameter Fail Rap; 024-375 Iot-Ess Communication Fail 24 Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

024-374 Registration Con PLL Parameter Fail RAP

BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. RegiCon adjustment value setting error detected by Controller (Incorrect
parameter instruction). Incorrect color registration adjustment value is sent from the IOT.
Procedure
Turn the power OFF then ON.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace MCU PWB
(PL
18.2)
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
Initial Issue
WorkCentre 5335 Family Service Documentation

024-375 IOT-ESS Communication Fail 24 RAP

BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. DLL receiving error detected by Controller (Incorrect parameter instruction).
An illegal instruction for IOT Port No., Timeout Time, or Pointer was detected.
Procedure
Turn the power OFF then ON.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace MCU PWB
Replace ESS PWB
07/2011
2-393
BUS Updated 12/2011
(PL
18.2)
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
Status Indicator RAPs