042-325 Main Motor Fail RAP

BSD-ON:
BSD 4.1 Main Drive Control
042-325 Main motor run fault.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
10. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Refer to the procedure that follows as necessary:
GP 6
How to Check a Motor.
Enter
dC330
code 042-003 to run the main motor,
Y
N
Check the +24V power supply to the main motor. The power supply is good.
Y
N
Check the power supply circuit to the main motor.
Check the items that follow:
The connection between the main motor ( P/J212) and the drive PWB ( P/J405) for
open circuit, short circuit or poor contact.
The drive gear for wear, damage or bearing blockage.
Load towards the main motor.
Install new components as necessary:
Main motor,
PL 40.10 Item
1.
Drive PWB,
PL 1.10 Item
3.
The fault may be intermittent. Check the connection between the main motor (
and the drive PWB (
P/J405
pin 4) for open circuit, short circuit or poor contact.
Install new components as necessary:
Drive PWB,
PL 1.10 Item
3.
ESS PWB,
PL 3.10 Item
6.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
PL 40.10 Item
1. The main motor runs.
042-330 Fuser Exhaust Fan Fail RAP
BSD-ON:
BSD 10.3 Fusing
042-330 Fuser exhaust fan fault.
Procedure
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
death or injury. Moving parts can cause injury.
Refer to the procedure that follows as necessary:
GP 6
How to Check a Motor.
Enter
dC330
code 042-050 to run the fuser exhaust fan. The fuser exhaust fan runs.
Y
N
Check the +24V power supply to the fuser exhaust fan. The power supply is good.
Y
N
Check the power supply circuit to the fuser exhaust fan.
Check the items that follow:
The connection between the fuser exhaust fan( P/J210) and the drive PWB (
J413) for open circuit, short circuit or poor contact.
Load towards the fuser exhaust fan.
Install new components as necessary:
Fuser exhaust fan,
Drive PWB,
The fault may be intermittent. Check the connection between the fuser exhaust fan (
pin 2) and the drive PWB (
P/J212
pin 2)
Install new components as necessary:
Drive PWB,
PL 1.10 Item
ESS PWB,
PL 3.10 Item
April 2017
2-447
WARNING
GP
10. Disconnect the power cord. Electricity can cause
PL 40.15 Item
4.
PL 1.10 Item
3.
P/J413
pin 2) for open circuit, short circuit or poor contact.
3.
6.
P/
P/J210
Status Indicator RAPs
042-325, 042-330