124-390 CRUM OEM Fail All (2) RAP
System Fail. All three CRUM OEM destinations are not set (0 or different values are set).
#Case-(2). The CRUM OEM destinations stored in three positions match but their values are
not set (0).
Procedure
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
•
Replace the machine, or replace the MCU Board
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
18.2). Reload Firmware
(GP
16)
07/2011
2-983
BUS Updated 12/2011
124-391 CRUM OEM Fail MCU (2) RAP
System Fail. One of CRUM OEM destinations is different from the others (IOT). #Case-(2).
One of the CRUM OEM destinations stored in three positions does not match (Data stored in
the MCU Board does not match).
Procedure
•
(Software available for
Machine ID/Billing
•
Enter
Machine ID/Billing
Data. Master SYS1 to resolve the problem. If the problem per-
sists, replace the MCU PWB
(PL
18.2).
(Software unavailable for
Machine ID/Billing
Reload Firmware
(GP
16). Replace the MCU PWB
•
Go to the Fault Code for the color that displays an error:
–
093-926
Toner CRUM Data Mismatch Fail RAP
Data)
Data)
(PL
18.2).
Status Indicator RAPs
124-390, 124-391