124-343 Crum Market Fail Sys 2 Rap; 124-344 All Billings Meter Types Mismatch Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

124-343 CRUM Market Fail SYS 2 RAP

System Fail. One of CRUM destinations is different from the others (SYS 2). One of the CRUM
destinations stored in three positions does not match (Data stored in the ESS PWB
does not match).
Procedure
(Software available for
Machine ID/Billing
Enter
Machine ID/Billing
Data. Master SYS2 to resolve the problem. If the problem per-
sists, replace the Cont NVM and the Cont PWB in order.
(Software unavailable for
Machine ID/Billing
Reload software
GP
16. If the problem still reoccurs, replace the ESS PWB
Go to the Fault Code for the color that displays an error:
093-926
Toner CRUM Data Mismatch Fail RAP
Status Indicator RAPs
124-343, 124-344
(PL
Data)
Data)
(PL
35.2).
BUS Updated 12/2011

124-344 All Billings Meter Types Mismatch RAP

BSD-ON:
BSD 3.8 - Electronic Billing
35.2)
System Fail. Billing Meter Type Fail (All the three are different from each other.) All the billing
meter types kept at multiple locations are different.
Procedure
Power OFF then ON. If the problem persists, perform the following:
Reload software
GP
16. Replace the MCU PWB
07/2011
2-972
(PL
18.2) and the ESS PWB
(PL
Initial Issue
WorkCentre 5335 Family Service Documentation
35.2).