091-913 Drum Cartridge Life End RAP
BSD-ON:
BSD 9.1 - CRU Life Control
Drum has reached the end of its life span.
Procedure
Replace the Drum
(PL
8.1).
Initial Issue
WorkCentre 5335 Family Service Documentation
091-914 Drum CRUM Communication Fail RAP
BSD-ON:
BSD 9.1 - CRU Life Control
Communication failure with Drum was detected.
Procedure
1.
Turn the power OFF and ON.
2.
Check the following:
•
The connection between the MCU PWB
for an open circuit and poor contact.
•
The connection terminals between the Drum CRUM PWB and the Drum CRUM
PWB for damage and foreign substances
•
The Drum CRUM PWB for contamination or disengagement
•
The Drum for improper installation
If no problems are found, replace the following parts in sequence:
•
Drum
•
MCU PWB
07/2011
2-827
BUS Updated 12/2011
P/J413
(PL
8.1)
(PL
18.2)
and the Drum CRUM PWB
P/J999
Status Indicator RAPs
091-913, 091-914