IQS12 Magnification Specification

Procedure
Use Side B of the Standard Test Pattern.
The tolerance for each magnification setting in the lead edge to trail edge direction and the
front to rear direction are listed in Table below.
Table 1 Magnification Specifications
Magnification(%)
Measurement
65
130+/-2mm
101
202+/-2mm
154
154+/-2mm
Refer to
Figure 1
for the areas to be measured. For 65% and 101%, use areas A and B for the
magnification in the lead edge to trail edge direction; and areas C and D for magnification in
the front to rear direction. For 154% use areas A and E for magnification in the lead edge to
trail edge direction; and areas C and F for magnification in the front to rear direction.
Initial Issue
WorkCentre 5335 Family Service Documentation
07/2011
3-27
BUS Updated 12/2011
Figure 1 Areas of Side B to be Measured