124-332 Contract Data Mismatch RAP
System Fail. Contract data mismatch. Case where the contract data on IOT side and Controller
side mismatches.
Procedure
Match the contract data on IOT and Controller.
Initial Issue
WorkCentre 5335 Family Service Documentation
124-333 ASIC RAP
A decompression error occurred in an ESS ASIC (Application Specific Integrated Circuit).
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Remove and re-install the System Memory
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
•
Replace ESS PWB
DIMM.)
07/2011
2-967
BUS Updated 12/2011
(PL
35.2).
(PL
35.2)
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
Status Indicator RAPs
124-332, 124-333