116-316 ESS RAM DIMM R/W Check RAP
An error is detected during the Read/Write operation of the ESS RAM DIMM.
Initial Actions
Power Off/On
Procedure
Turn OFF then ON the power. If the problem persists, perform the following:
1.
Remove and insert ESS RAM DIMM.
2.
Check the sw version of the controller sw - update if required
3.
Replace ESS RAM DIMM.
4.
Replace the ESS PWB
(PL
35.2).
Initial Issue
WorkCentre 5335 Family Service Documentation
116-317 Standard ROM DIMM Check Fail RAP
An error is detected when the ESS ROM ESS ROM DIMM was checked.
Initial Actions
Power Off/On
Procedure
Turn OFF then ON the power. If the problem persists, perform the following:
1.
Remove and insert ESS ROM DIMM.
2.
Check the sw version of the controller sw - update if required
3.
Replace ESS ROM DIMM.
4.
Replace the ESS PWB
07/2011
2-851
BUS Updated 12/2011
(PL
35.2).