116-372 Formatter RAP

An internal shutdown occurred after a processing error.
Initial Actions
Power Off/On
Procedure
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
Check the sw version of the controller sw - update if required
Replace RAM DIMM on ESS PWB
(PL
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Initial Issue
WorkCentre 5335 Family Service Documentation
35.2)
BUS Updated 12/2011

116-373 Dynamic DNS Software RAP

An internal shutdown occurred after a DDNS (Dynamic Domain Name System) processing
error.
Initial Actions
Power Off/On
Procedure
(PL
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
SNTP
NetWare
Salutation IO
SMB
Port 9100
USB
lpd
FTP Serv
MailIO
IPP
Check the sw version of the controller sw - update if required
Replace ESS PWB
(PL
07/2011
2-875
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs