024-980 Stacker Tray Full RAP
BSD-ON:
BSD 12.24 - Office Finisher LX Stacker Tray Control
The output paper stacked on the Finisher Stacker Tray reaches capacity (for mixed paper size).
There are a number of different conditions that can cause this fault and those conditions differ
for the different finishers.
Initial Actions
•
Remove the paper from the Stacker Tray
•
Power Off/On
Procedure
•
Go to the
012-211 (Integrated Finisher)
•
Remove the paper from the Stacker Tray
•
Check the Stack Height Sensor 1
Component Control
the sensor, and Stack Height Sensor 2
•
Check the wiring for an open or short circuit repair as required.
•
Check the sw version of the controller sw - update if required
•
Replace the defective Sensor
(PL
23.11).
•
If the fault is still occurring replace the Finisher PWB
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
Status Indicator RAPs
024-980, 024-982
RAP.
[012-264] and block and unblock
Component Control
[012-265].
(PL
23.16).
BUS Updated 12/2011
024-982 Finisher Stacker Tray Lower Safety RAP
BSD-ON:
BSD 12.24 - Office Finisher LX Stacker Tray Control
Stacker tray moved down past the lower limit position.
Initial Actions
Power Off/On
Procedure
•
Go to
012-213
Stacker Tray Lower Limit Failure RAP (LX),
Stack Tray Fail.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
07/2011
2-426
012-211 (Integrated Finisher)
(GP
16)
Initial Issue
WorkCentre 5335 Family Service Documentation