124-334 ESS ROM 1 RAP
An error was detected in ESS ROM 1.
Procedure
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Remove and re-install the System Memory
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
(PL
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
Status Indicator RAPs
124-334, 124-335
(PL
35.2).
35.2)
BUS Updated 12/2011
124-335 Font ROM RAP
The Font ROM could not be detected.
Initial Actions
Power Off/On
Procedure
•
Turn the power OFF then ON. If the problem persists, perform the following procedure to
repair it.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Pull out and insert or replace the Font ROM.
•
Remove and re-install the System Memory
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB and RAM
DIMM.)
07/2011
2-968
(PL
35.2).
(PL
35.2)
WorkCentre 5335 Family Service Documentation
Initial Issue