116-325 ESS Fan RAP

The ESS fan failed.
Procedure
Turn the power OFF then ON. Replace the ESS fan
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
35.2).
07/2011
BUS Updated 12/2011

116-328 L2 Cache Fail RAP

A failure was detected in the Level 2 Cache built in the CPU.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
Check the sw version of the controller sw - update if required
Replace RAM DIMM on ESS PWB
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)