116-365 Spool RAP
An internal shutdown occurred after an SPL processing error.
Initial Actions
Power Off/On
Procedure
•
Check the HDD electrical connections
•
Check the sw version of the controller sw - update if required
•
If the problem persists perform
Hard Disk Failure Prediction
•
Perform
GP 14
- only the first two parts - make sure to follow sequence and heed cau-
tions
1.
Job Log Clear Mode
2.
HDD Initialize Mode
•
Replace HDD
(PL
35.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Status Indicator RAPs
116-365, 116-366
(PL
35.2).
Test.
BUS Updated 12/2011
116-366 Software Report RAP
An internal shutdown occurred after a reporting error.
Initial Actions
Power Off/On
Procedure
•
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the ESS, MCU all PWBs connected to them (RAM, Firmware
module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace RAM DIMM on ESS PWB
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
07/2011
2-872
(PL
35.2)
WorkCentre 5335 Family Service Documentation
(PL
Initial Issue