092-315 ATC Fail RAP
BSD-ON:
BSD 9.3 - Development and Toner Dispense Control
The frequency at which the ATC Average Fail or the ATC Amplitude Fail has been occurring
has exceeded the threshold value.
NOTE: •
Although this Fault can be cleared by turning the power OFF and ON and it will be possi-
ble to output a few sheets of printouts, when this Fault has occurred a certain number of
times, it will no longer be clearable by turning the power OFF and ON. To clear it, clear the
value of NVM location [752-022] (ATC Average Fail) or NVM location [752-023] (ATC
Amplitude Fail) to "0"
(NVM
Read/Write). If the machine is not repaired back to normal
status, this Fault will occur again during the operation.
•
When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The connection between the MCU PWB
J615
for open circuit, short circuit, and poor contact
•
The Toner Dispense Motor for revolution failure:
•
The Toner Cartridge for internal toner blockage
If no problems are found, replace the following parts in sequence:
•
Drum Cartridge
(PL
8.1)
•
MCU PWB
(PL
18.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
P/J413
and the Xero/Developer Cartridge
Component Control
[093-002]
(PL
8.2)
BUS Updated 12/2011
092-323 Dispense Fail RAP
BSD-ON:
BSD 9.3 - Development and Toner Dispense Control
Toner Cartridge becomes Empty despite less use of Toner amount.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The connection between the MCU PWB
J615
for open circuit, short circuit, and poor contact
•
The Toner Dispense Motor for revolution failure:
•
The Toner Cartridge for internal toner blockage
If no problems are found, replace the following parts in sequence:
•
Drum Cartridge
(PL
8.1)
•
MCU PWB
(PL
18.2)
P/
07/2011
2-831
P/J413
and the Xero/Developer Cartridge
Component Control
[093-002]
(PL
8.2)
Status Indicator RAPs
092-315, 092-323
P/