024-357 Iot-Ess Communication 17 Rap; 024-358 Iot-Ess Communication 18 Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

024-357 IOT-ESS Communication 17 RAP

BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
IOT-ESS Communication Failure 17. ESS PWB detected a communication failure between
IOT and ESS.
Initial Actions
Power Off/On
Procedure
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Check that connectors on the MCU PWB MCU PWB
35.2) are securely connected. Disconnect then reconnect the IIT, Control Panel, ESS,
MCU all PWBs connected to them (RAM, Firmware module, EEPROM)
Check the sw version of the controller sw. If the problem continues, reload Software
16).
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
If the problem persists, replace the MCU PWB MCU PWB
Initial Issue
WorkCentre 5335 Family Service Documentation

024-358 IOT-ESS Communication 18 RAP

BSD-ON:
BSD-ON:
IOT-ESS Communication Failure 18. ESS PWB detected a communication failure between
IOT and ESS.
Initial Actions
Power Off/On
Procedure
(PL
18.2) and on the ESS PWB
(PL
(GP
(PL
18.2)
07/2011
2-385
BUS Updated 12/2011
BSD 3.1 - ESS - MCU Communication
BSD 16.1 - ESS
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Check that connectors on the MCU PWB MCU PWB
35.2) are securely connected. Disconnect then reconnect the IIT, Control Panel, ESS,
MCU all PWBs connected to them (RAM, Firmware module, EEPROM)
Check the sw version of the controller sw. If the problem continues, reload Software
16).
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
If the problem persists, replace the MCU PWB MCU PWB
(PL
18.2) and on the ESS PWB
(PL
(GP
(PL
18.2)
Status Indicator RAPs
024-357, 024-358

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series