REP 5.7 Left Counter Balance

Parts List on
PL 51.3
Removal
Left/Right Counter Balance is identified by its spring pressure.
Left Counter Balance: strong spring pressure
Right Counter Balance: weak spring pressure
1.
Switch off the power and disconnect the power cord.
2.
Remove the DADF Front Cover.
(REP
3.
Remove the DADF Rear Cover.
(REP
4.
Remove the DADF.
(REP
5.1)
5.
Remove the DADF Document Tray.
(REP
6.
Remove the DADF Feeder Assembly.
7.
Remove the screws that secure the Tie Plate.
(1) Remove the self-tapping screw.
(2) Remove the Ground Plate.
(3) Remove the self-tapping screws (x2).
Figure 1 Tie Plate Screws
8.
Remove the Left Counter Balance.
(Figure
(1) Remove the self-tapping screws (Large: x2).
(2) Remove the Left Counter Balance.
Initial Issue
WorkCentre 5335 Family Service Documentation
CAUTION
5.3)
5.4)
5.9)
(REP
5.5)
(Figure
1)
2)
BUS Updated 12/2011
Figure 2 Left Counter Balance
Replacement
1.
To install, carry out the removal steps in reverse order.
2.
When installing the Left Counter Balance, align the hole of the Left Counter Balance to
the positioning boss of the Frame.
Figure 3 Left Counter Balance Hole Alignment
3.
Align the Ground Plate to the positioning boss.
07/2011
4-19
(Figure
3)
(Figure
4)