024-979 Low Staples Rap (Integrated Finisher); 024-979 Low Staples Rap (Finisher Lx) - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

024-979 Low Staples RAP (Integrated Finisher)

BSD-ON:
BSD 12.5 - Integrated Finisher Staple Control
Staples Near Empty or Staple-feed failure.
Initial Actions
Power Off/On
Procedure
Execute
Component Control
[012-242 Low Staple Sensor]. Install and remove the Staple Car-
tridge. The display changes.
Y
N
Check the Staple Cartridge for failure or foreign substances. There are no foreign sub-
stances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the wires between
P/J8731
and
short circuit. The wires are OK.
Y
N
Repair as required.
Measure the voltage between the Finisher PWB
age is approx. +5VDC.
Y
N
Replace the Finisher PWB
(PL
22.7).
Measure the voltage between the Finisher PWB P/J8701-7 (+) and GND (-). Install and
remove the Staple Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB
(PL
22.7).
Replace the Staple Assembly
(PL
22.4) If the problem persists, replace the Finisher PWB
(PL
22.7).
Check the sw version of the controller sw - update if required. Replace the Finisher PWB
22.7) If the problem persists, replace the MCU PWB
Initial Issue
WorkCentre 5335 Family Service Documentation
P/J8701
for a loose connection, or an open or a
P/J8701
-5 (+) and GND (-). The
(PL
18.2).
BUS Updated 12/2011

024-979 Low Staples RAP (Finisher LX)

BSD-ON:
BSD 12.21 - Office Finisher LX Staple Control
Staples Near Empty or Staple-feed failure.
Initial Actions
Power Off/On
Procedure
Execute
Component Control
[012-242 Low Staple Sensor]. Install and remove the Staple Car-
tridge. The display changes.
Y
N
Check the Staple Cartridge for failure or foreign substances. There are no foreign sub-
stances and nothing has failed.
Y
N
Repair the failure and remove the foreign substances.
Check the wires between
short circuit. The wires are OK.
Y
N
Repair as required.
volt-
Measure the voltage between the Finisher PWB J8886-5 (+) and GND (-). The voltage
is approx. +5VDC.
Y
N
Replace the Finisher PWB
Measure the voltage between the Finisher PWB J8886-7 (+) and GND (-). Install and
remove the Staple Cartridge. The voltage changes.
Y
N
Replace the Finisher PWB
Replace the Staple Assembly
(PL
23.16).
(PL
Check the sw version of the controller sw - update if required. Replace the Finisher PWB
23.16).
07/2011
2-425
J8886
and
P/J8981
for a loose connection, or an open or a
(PL
22.7).
(PL
23.16).
(PL
23.4) If the problem persists, replace the Finisher PWB
Status Indicator RAPs
024-979, 024-979
(PL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents