045-310 Image Ready NG RAP
BSD-ON:
BSD 3.1 - ESS-MCU Communication
A Controller image preparation failure was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check whether there is poor connection or foreign substances at
the following connectors.
•
Between the ESS PWB
P/J320
•
Between the ESS PWB
P/J1323
If no problems are found, replace the following parts in sequence:
•
Check the sw version of the controller sw - update if required
•
MCU PWB
(PL
18.2)
•
ESS PWB
(PL
35.2)
Initial Issue
WorkCentre 5335 Family Service Documentation
and the MCU PWB
P/J402
and the MCU PWB
P/J403
BUS Updated 12/2011
045-311 Controller Communication Fail RAP
BSD-ON:
BSD 3.1 - ESS-MCU Communication
Communication error between ESS PWB and MCU PWB was detected.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
1.
Turn the power OFF and ON.
2.
Turn the power OFF and check whether there is poor connection or foreign substances at
the following connectors.
•
Between the ESS PWB
P/J320
•
Between the ESS PWB
P/J1323
If no problems are found, replace the following parts in sequence:
•
Check the sw version of the controller sw - update if required
•
MCU PWB
(PL
18.2)
•
ESS PWB
(PL
35.2)
07/2011
2-765
and the MCU PWB
P/J402
and the MCU PWB
P/J403
Status Indicator RAPs
045-310, 045-311