024-372 IOT-ESS Communication Fail 22 RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. Sending error detected by Controller (Incorrect parameter instruction). An
illegal instruction for IOT Port No., Timeout Time, Pointer, or Transfer Size was detected.
Procedure
•
Turn the power OFF then ON.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace MCU PWB
(PL
18.2)
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
Status Indicator RAPs
024-372, 024-373
024-373 IOT-ESS Communication Fail 23 RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. DLL communication failure recovery error detected by Controller. When a
message packet is sent from the Controller, the ACK packet from the IOT cannot be received
within the specified time after the specified number of retries.
Procedure
•
Turn the power OFF then ON.
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw - update if required
•
Replace MCU PWB
•
Replace ESS PWB
07/2011
2-392
BUS Updated 12/2011
(PL
18.2)
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
WorkCentre 5335 Family Service Documentation
Initial Issue