024-372 IOT-ESS Communication Fail 22 RAP

BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. Sending error detected by Controller (Incorrect parameter instruction). An
illegal instruction for IOT Port No., Timeout Time, Pointer, or Transfer Size was detected.
Procedure
Turn the power OFF then ON.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace MCU PWB
(PL
18.2)
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
Status Indicator RAPs
024-372, 024-373

024-373 IOT-ESS Communication Fail 23 RAP

BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
Sub System Fail. DLL communication failure recovery error detected by Controller. When a
message packet is sent from the Controller, the ACK packet from the IOT cannot be received
within the specified time after the specified number of retries.
Procedure
Turn the power OFF then ON.
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Disconnect then reconnect the IIT, Control Panel, ESS, MCU all PWBs connected to them
(RAM, Firmware module, EEPROM)
Check the sw version of the controller sw - update if required
Replace MCU PWB
Replace ESS PWB
07/2011
2-392
BUS Updated 12/2011
(PL
18.2)
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
WorkCentre 5335 Family Service Documentation