116-363 BMLinkS/Print Service Software RAP
An internal shutdown occurred after an SNMP processing error.
Initial Actions
Power Off/On
Procedure
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
SNTP
NetWare
Salutation IO
SMB
Port 9100
USB
lpd
FTP Serv
MailIO
IPP
Check the sw version of the controller sw - update if required
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Initial Issue
WorkCentre 5335 Family Service Documentation

116-364 Timer RAP

A timer failure is detected in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are correctly con-
nected.
Y
N
(PL
Connect the connectors.
Turn on the power again. The problem persists.
Y
N
Return to Service Call Procedures.
Check the sw version of the controller sw - update if required. Replace the ESS PWB
35.2).
07/2011
2-871
BUS Updated 12/2011
(PL
Status Indicator RAPs
116-363, 116-364