116-363 BMLinkS/Print Service Software RAP
An internal shutdown occurred after an SNMP processing error.
Initial Actions
Power Off/On
Procedure
•
Change the system data 700-530 to "0" and disable the automatic startup boot operation
at SystemFail (make sure to reset to 1 when complete
•
Remove and re-install or replace the System Memory and Page Memory DIMMs
35.2).
•
Specially check for faulty ports or Net connection. Check which of the following ports is
faulty.
–
SNTP
–
NetWare
–
Salutation IO
–
SMB
–
Port 9100
–
USB
–
lpd
–
FTP Serv
–
MailIO
–
IPP
–
Check the sw version of the controller sw - update if required
–
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS PWB)
Initial Issue
WorkCentre 5335 Family Service Documentation
116-364 Timer RAP
A timer failure is detected in the ESS PWB.
Initial Actions
Power Off/On
Procedure
Check the connection of each ESS PWB connector. The connectors are correctly con-
nected.
Y
N
(PL
Connect the connectors.
Turn on the power again. The problem persists.
Y
N
Return to Service Call Procedures.
Check the sw version of the controller sw - update if required. Replace the ESS PWB
35.2).
07/2011
2-871
BUS Updated 12/2011
(PL
Status Indicator RAPs
116-363, 116-364