Rep 6.5 Front/Rear Carriage Cable - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

Figure 2 CCD Flexible Print Cable
5.
Replace the CCD Lens Assembly
(Figure
NOTE: When removing the CCD Lens Assembly, never remove the screws (Red: x2) of
the jig pin.
(1) Remove the screws (x4).
(2) Replace the CCD Lens Assembly.
(3) Secure the CCD Lens Assembly by using the screws (x4).
Figure 3 CCD Lens Assembly
6.
Connect the CCD Flexible Print Cable.
7.
Install the APS Sensor and Lens Cover.
8.
Install the Platen Glass.
9.
Perform
ADJ
6.1.
10. Reinstall all removed parts.
Repairs & Adjustments
REP 6.4, REP 6.5
3)
BUS Updated 12/2011

REP 6.5 Front/Rear Carriage Cable

Parts List on
PL 1.3
Removal
The burr at the edge of the IIT Frame might cause injury. Be very careful when disconnect the
Carriage.
NOTE: The front and rear coatings of the Carriage Cable are different.
Front: Silver
Rear: Black
NOTE: Only the replacement procedure for the Rear Carriage Cable is described here. The
replacement procedures for the Front Carriage Cable is the same as for the Rear Carriage
Cable.
NOTE: The Carriage Cables must be replaced one at a time. Never remove both front and rear
cables at the same time.
1.
Switch off the power and disconnect the power cord.
2.
Open the DADF or the Platen Cover.
3.
Remove the following parts:
Platen Glass
(REP
6.3)
Control Panel Assembly
(REP
IIT Left Cover
(PL
1.1)
4.
Take note of the installation position of the Front Support
Mark position
Figure 1 Front Support Installation Position
5.
Remove the DADF Platen Glass
(1) Remove the screw.
(2) Remove the Front Support.
(3) Remove the DADF Platen Glass.
07/2011
4-40
CAUTION
6.11)
(Figure
1)
(Figure
2)
WorkCentre 5335 Family Service Documentation
Initial Issue

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents