077-106 Exit Sensor 1 On Jam RAP
BSD-ON:
BSD 4.1 - Main Drive Control
BSD-ON:
BSD 10.2 - Fusing
The Fuser Exit Sensor does not turn ON within the specified time after the Registration Clutch
On.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Procedure
Check the following:
•
The Fuser Exit Sensor for failure:
Component Control
•
A paper transportation failure due to a foreign substance/burr on the paper path
•
The Fuser Exit Sensor for contamination, improper installation, and Actuator operation
failure
•
Each Takeaway Roll and Pinch Roll for contamination, wear, and revolution failure
•
The Registration Roll and Pinch Roll for contamination, wear, and revolution failure
•
The BTR for contamination, wear, and revolution failure
•
The Fuser for wound up, stuck paper
•
The Fuser Drive Gear for wear and damage
•
Use of paper out of spec
Reload the machine software
(GP
16). If no problems are found, replace the MCU PWB
18.2).
Status Indicator RAPs
077-106, 077-109
077-109 Exit Sensor 2 On Jam RAP
BSD-ON:
BSD-ON:
After the Fuser Exit Sensor turned ON, the Exit 2 Sensor did not turn ON within the specified
time.
NOTE: When turning the power OFF, turn OFF the power switch first and then the main power
switch.
Initial Actions
Check the following:
[077-101]
(PL
7.1)
•
•
•
•
•
•
•
Procedure
Check the following:
(PL
•
•
•
•
Reload the machine software
18.2).
07/2011
2-804
BUS Updated 12/2011
BSD 10.3 - Exit Transportation
BSD 10.4 - Exit 2 Drive
A paper transportation failure due to a foreign substance/burr on the paper path
Each Exit Roll and Pinch Roll for contamination, wear, and revolution failure
The Fuser for wound up, stuck paper
Each Exit Roll Drive Gear for wear and damage
The Exit 1 Gate for operation failure
Use of paper out of spec
The Exit 2 Sensor for contamination, improper installation, and Actuator operation failure
The Exit 2 Sensor for failure:
Component Control
The connection between the Exit 2 Sensor
circuit, short circuit, and poor contact
The Exit 2 Motor for revolution failure:
Component Control
The Exit Gate Solenoid for failure:
Component Control
(GP
16). If no problems are found, replace the MCU PWB
WorkCentre 5335 Family Service Documentation
[077-100]
(PL
17.4)
P/J115
and the MCU PWB
P/J411
for open
[077-015]
(PL
17.5)
[077-004]
(PL
17.4)
(PL
Initial Issue