024-351 IOT-ESS Communication 11 RAP
BSD-ON:
BSD 3.1 - ESS - MCU Communication
BSD-ON:
BSD 16.1 - ESS
ESS PWB detected a communication failure between IOT and ESS
Initial Actions
Power Off/On
Procedure
•
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
•
Check that connectors on the MCU PWB MCU PWB
35.2) are securely connected. Disconnect then reconnect the IIT, Control Panel, ESS,
MCU all PWBs connected to them (RAM, Firmware module, EEPROM)
•
Check the sw version of the controller sw. If the problem continues, reload Software
16).
•
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
•
If the problem persists, replace the MCU PWB MCU PWB
Status Indicator RAPs
024-351, 024-352
024-352 IOT-ESS Communication 12 RAP
BSD-ON:
BSD-ON:
IOT-ESS Communication Failure 12. ESS PWB detected a communication failure between
IOT and ESS.
Initial Actions
Power Off/On
Procedure
•
(PL
18.2) and on the ESS PWB
(PL
•
(GP
•
•
(PL
18.2)
•
07/2011
2-382
BUS Updated 12/2011
BSD 3.1 - ESS - MCU Communication
BSD 16.1 - ESS
Ensure that the customer is programming a job within the parameters of the machine uti-
lizing the UI.
Check that connectors on the MCU PWB MCU PWB
35.2) are securely connected. Disconnect then reconnect the IIT, Control Panel, ESS,
MCU all PWBs connected to them (RAM, Firmware module, EEPROM)
Check the sw version of the controller sw. If the problem continues, reload Software
16).
Replace ESS PWB
(PL
35.2) (If not fixed by this, reinstall the original ESS & MCU)
If the problem persists, replace the MCU PWB MCU PWB
WorkCentre 5335 Family Service Documentation
(PL
18.2) and on the ESS PWB
(PL
(GP
(PL
18.2)
Initial Issue