Rep 12.7 Exit Roll Assembly - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

Figure 2 Removing the Set Clamp Home Sensor Assembly
6.
Remove the Set Clamp Home Sensor
(1)Remove Set Clamp Home Sensor from Bracket.
(2)Disconnect Connector.
Figure 3 Removing the Set Clamp Home Sensor
Replacement
1.
Reverse the removal procedure for replacement.
Repairs & Adjustments
REP 12.6, REP 12.7
(Figure
3):
BUS Updated 12/2011

REP 12.7 Exit Roll Assembly

Parts List on
PL 22.4
Removal
NOTE: The Integrated Office Finisher is available for use in several different machines. The
color of the Covers may be different from product to product, however, the repair procedures
are the same.
1.
Switch off the power and disconnect the power cord.
2.
Remove the Integrated Office Finisher from the machine
3.
Remove the Inner Front Cover
4.
Remove the Rear Cover
(PL
22.1)
5.
Remove the Left Cover
(PL
22.2)
6.
Remove the Upper Frame Section
(1)Remove Screw and Bracket.
(2)Remove Screws (2).
(3)Remove Screw and Bracket.
(4)Remove Screws (2).
(5)Remove the Upper Frame Section
07/2011
4-102
(REP
12.1).
(PL
22.1)
(Figure
1):
WorkCentre 5335 Family Service Documentation