Avaya S8700 Maintenance Manual page 272

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
Table 7-3. Common Error Codes for Busyout, Release, Test, and
Reset Commands — Continued
Error
Command
Code
Result
EXTRA BD
1
FAIL
2
FAIL
FAIL
PASS
7-16
Issue 1 May 2002
Description/Recommendation
This result can appear for Maintenance/Test, Call Classifier, Tone
Detector, Announcement, and Speech Synthesis circuit packs. Each of
these circuit packs has restrictions on how many can be installed in the
system or in a port network. The restrictions are as follows:
TN771D Maintenance/Test: 1 / port network
TN748 Tone Detector: 50 / system
TN744 Call Classifier: 25 / system
Speech Synthesizer: 40 / system
TN750 Announcement: 1 / system
Remove any extra circuit packs.
For reset commands, the circuit pack was not successfully halted.
For reset commands, the circuit pack was not successfully restarted after
being halted. For both results, replace the circuit pack.
See the applicable maintenance object in
''Maintenance-Object Repair
The requested action successfully completed. If the command was a
reset, the circuit pack is now running and should be tested.
Chapter 8,
Procedures''.
Continued on next page
555-233-143