Avaya S8700 Maintenance Manual page 264

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Commands
Table 7-2. Less-Common Test Command Parameters — Continued
Parameter
Range
clear
G700 Media Gateway Parameters
The parameters, GGGVSPP, may apply to select SAT command run against an
MO in the system; for example, test port 002V204
002V204
7-8
Issue 1 May 2002
Default
Meaning
Used with test commands, this specifies that the test
sequence is to be repeated until any active alarms against
the maintenance object is cleared by the passing of tests or
until any test in the sequence fails.
If no such alarms are active, the sequence is run once.
The long clear combination clears every alarm against the
maintenance object if no errors are encountered. The
short clear combination clears only alarms pertinent to the
tests in the short sequence.
!
CAUTION:
If every tests passes, the long clear
combination clears every error counter. If
firmware counters are cleared while an actual
problem exists, customer service may degrade
due to calls being routed over faulty
components.
002 is the Media Gateway Number
V indicates that this system is a G700 Media Gateway
2 is the slot number from 1 to 4
04 is the port number from 1 to 22.
Continued on next page
555-233-143