Avaya S8700 Maintenance Manual page 2080

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 8-550. Analog Ring Generator Error Log Entries
Error
Aux
Type
Data
Associated Test
1
0
0
Any
1
Analog Ring Generator Query
(#118)
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
Analog Ring Generator Initialization test (#117), you may also clear errors
generated from other tests in the testing sequence.
Table 8-551. Multicarrier Cabinet
Order of Investigation
Analog Ring Generator Initialization test (#117)
Analog Ring Generator Query test (#118)
Battery and Battery Charger Query test (#5) (a)
AC Power Query test (#78) (b)
OLS Query test (Carrier E) (#127) (c)
OLS Query test (Carrier D) (#127) (c)
OLS Query test (Carrier A) (#127) (c)
OLS Query test (Carrier B) (#127) (c)
OLS Query test (Carrier C) (#127) (c)
Emergency Transfer Query test (#124) (d)
Cabinet Sensors Query test (#122) (e)
External Alarm Lead Query test (#120) (f)
1.
D = Destructive, ND = Nondestructive
8-1358
Issue 1 May 2002
Alarm
On/Off
Level
Board
Test to Clear Value
Any
Any
test environment UU
MAJOR
ON
test environment UU r 3
Short Test
Long Test
Sequence
Sequence
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
D/ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
555-233-143