Avaya S8700 Maintenance Manual page 2082

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures
Analog Ring Generator Initialization Test (#117)
The Analog Ring Generator Initialization test sends a request to the active TN768,
TN780, TN2182 Tone-Clock or TN2312AP IPSI circuit pack's Tone-Clock circuit to
monitor the voltage. The Tone-Clock responds with an error if the ringing voltage
falls too low.
Table 8-553. Test #117 Analog Ring Generator Initialization Test
Error
Test
Code
Result
Description / Recommendation
1,
ABORT
The system software is unable to determine the active Tone-Clock circuit pack,
1000,
unable to allocated the resources necessary to run the test, or unable to send a
1001,
down link message.
1003,
1. Wait for the green LED on the active Tone-Clock to go out; use the status
1115,
2012,
2. Rerun the test. If the test aborts again, see
2100
2000
ABORT
Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve every other Tone-Clock
2. Rerun the test.
PASS
The active Tone-Clock has successfully been enabled to monitor the ringing
voltage level.
8-1360
Issue 1 May 2002
port-network command to determine the active Tone-Clock circuit pack.
problem first.
''TDM-CLK (TDM Bus
Clock)''.
555-233-143

Advertisement

Table of Contents
loading

Table of Contents