Ralm-Svc (Remote Alarm Service) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures

RALM-SVC (Remote Alarm Service)

MO's Name (in
Alarm Log)
RALM-SVC
RALM-SVC
For the RALM-SVC MO, maintenance software does special periodic testing
every 60 seconds. These tests verify that the standby media server's
components are operating correctly.
Alarm Log Entries
Table 8-538. RALM SVC Alarm Log Entries
EVENT
Aux
ID#
Data
Associated Test
1 (a)
SME_ARB test
2 (b)
Standby_PN Check test
Notes:
a. Event ID #1
Remote Alarm Service functionality. The test queries the standby media
server to find out whether it can generate alarms. (Both media servers
must have their own alarm-generation utilities.) If the test fails three
consecutive times, the following Super alarm is logged:
b. Event ID #2
1. Queries the standby media server about the state of health of its
2. Compares the acquired information to an administered value
A failure indicates that a mismatch occurred and that the standby media
server is out of sync. If this test fails 2 consecutive times, the following
Major alarm is logged:
System Technician-Demanded Tests: Descriptions
and Error Codes
This MO provides no on-demand tests for system technicians.
8-1332
Issue 1 May 2002
Alarm
Level
Initial Command to Run
SUPER
None
MAJOR
None
Alarm
Level
SUPER
MAJOR
failed — This periodic test verifies the Arbiter's
SME_ARB test
#1,ACT,SME,A,1,MIN,Far-end alarm service is down
Standby_PN_Check test
PNs
#1,ACT,SME,A,2,MAJ,Standby Port-Network check failed
Full Name of MO
Remote Alarm Service
Remote Alarm Service
On/Off
Linux Test to Clear
Board
Value
ON
testdupboard
ON
testdupboard
Continued on next page
failed — This periodic test:
555-233-143

Advertisement

Table of Contents
loading