Maintenance-Object Repair Procedures
Table 8-546. Test #11 Digital Line Electronic Power Feed Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call. Enter display port UUCSSpp to determine the station
extension or attendant number of the port. Use status station or status
attendant to determine the service state of the port. If the port is in use, wait
until the port is idle before testing. Attendants are always in use (off-hook) if
the handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals up to
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Electronic Power Feed test passed. The message to turn on the power to the
station was successfully sent to the port.
1. Although this test will never actually return a FAIL result except for the
2. If Error Type 767 appears in the Error Log, the test sensed no problems
3. If Error Type 769 appears in the Error Log, this indicates some problem
8-1350
Issue 1 May 2002
5 times.
Internal system error described above, it will log an error indicating the real
results of the test. Check the Error Log for any entries with Error Types
767 or 769 after the test completes.
with the power to the station. To verify that the station is powered up
correctly, run a self-test on the station and verify that every feature button
is operating.
with the power to the station. Check for a short in the wiring, a damaged
jack, a defective voice terminal, or an incorrect type of terminal.
Continued on next page