7.4.3 Action-Qualifier Submodule Registers
Figure 7-99
through
submodule register definitions.
Figure 7-99. Action-Qualifier Output A Control Register and Mirror Register (AQCTLA / AQCTLAM)
15
Reserved
7
6
CAD
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 7-49. Action-Qualifier Output A Control Register and Mirror Register (AQCTLA / AQCTLAM)
Bit
Field
15-12
Reserved
11-10
CBD
9-8
CBU
7-6
CAD
5-4
CAU
3-2
PRD
SPRUH22I – April 2012 – Revised November 2019
Submit Documentation Feedback
Figure 7-102
and
Table 7-49
12
R-0
5
4
CAU
R/W-0
Field Descriptions
Value
Description
Reserved
Action when the time-base counter equals the active CMPB register and the counter is
decrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPB register and the counter is incrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPA register and the counter is decrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPA register and the counter is incrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the period.
Note: By definition, in count up-down mode when the counter equals period the direction is defined
as 0 or counting down.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
Copyright © 2012–2019, Texas Instruments Incorporated
through
Table 7-52
provide the action-qualifier
11
10
CBD
R/W-0
3
2
PRD
R/W-0
C28 Enhanced Pulse Width Modulator (ePWM) Module
Registers
9
8
CBU
R/W-0
1
0
ZRO
R/W-0
749