5.4.3.5
Flash Bank Pump Control Register 1 (FBPRDY)
31
15
14
PUMPRDY
R-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-118. Flash Bank Pump Control Register (FBPRDY) Field Descriptions
Bit
Field
31-16
Reserved
15
PUMPRDY
14-1
Reserved
0
BANKRDY
5.4.3.6

Flash Bank Pump Control Register 1 (FPAC1)

31
Reserved
15
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-119. Flash Bank Pump Control Register 1 (FPAC1) Field Descriptions
Bit
Field
31-27
Reserved
26-16
PSLEEP
15-1
Reserved
SPRUH22I – April 2012 – Revised November 2019
Submit Documentation Feedback
Figure 5-114. Flash Bank Pump Control Register (FBPRDY)
Value
Description
Reserved
Pump Ready. Pump Ready is a read-only bit which allows software to determine if the pump is
ready for flash access before attempting the actual access. If an access is made to a bank when
the pump is not ready, wait states are asserted until it becomes ready.
0
Pump is not ready.
1
Pump is ready, in active power state.
Reserved
Bank Ready. This is a read-only register which allows software to determine if the C28x bank is
ready for Flash access before the access is attempted.
Note: User should wait for both the pump and the bank to be ready before attempting an access.
0
C28x bank is not ready.
1
C28x bank is in active power mode and is ready for access.
Figure 5-115. Flash Bank Pump Control Register 1 (FPAC1)
R-0
Reserved
R-0
Value
Description
Reserved
Pump sleep. These bits contain the starting count value for the charge pump sleep down counter.
While the charge pump is in sleep mode, the power mode management logic holds the charge
pump sleep counter at this value. When the charge pump exits sleep power mode, the down
counter delays from 0 to PSLEEP prescaled SYSCLK clock cycles before putting the charge pump
into active power mode.
Note: The pump sleep down counter uses the same prescaled clock as Bank sleep down counter
which is divided by 2 of input SYSCLK.
Reserved
Copyright © 2012–2019, Texas Instruments Incorporated
Reserved
R-0
Reserve
R-0
27
26
Flash Registers
1
0
BANKRDY
R-0
16
PSLEEP
R/W-0x64
1
0
PMPPWR
R/W-0
Internal Memory
16
527