Action-Qualifier Output B Control Register And Mirror Register (Aqctlb / Aqctlbm); Action-Qualifier Output B Control Register And Mirror Register (Aqctlb / Aqctlbm) Field Descriptions - Texas Instruments Concerto F28M35 Series Technical Reference Manual

Table of Contents

Advertisement

Registers
Table 7-49. Action-Qualifier Output A Control Register and Mirror Register (AQCTLA / AQCTLAM) Field
Bit
Field
1-0
ZRO
Figure 7-100. Action-Qualifier Output B Control Register and Mirror Register (AQCTLB / AQCTLBM)
15
Reserved
7
6
CAD
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 7-50. Action-Qualifier Output B Control Register and Mirror Register (AQCTLB / AQCTLBM)
Bit
Field
15-12
Reserved
11-10
CBD
9-8
CBU
7-6
CAD
5-4
CAU
750
C28 Enhanced Pulse Width Modulator (ePWM) Module
Descriptions (continued)
Value
Description
Action when counter equals zero.
Note: By definition, in count up-down mode when the counter equals 0 the direction is defined as 1
or counting up.
00
Do nothing (action disabled)
01
Clear: force EPWMxA output low.
10
Set: force EPWMxA output high.
11
Toggle EPWMxA output: low output signal will be forced high, and a high signal will be forced low.
12
R-0
5
4
CAU
R/W-0
Field Descriptions
Value
Description
Reserved
Action when the counter equals the active CMPB register and the counter is decrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxB output low.
10
Set: force EPWMxB output high.
11
Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPB register and the counter is incrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxB output low.
10
Set: force EPWMxB output high.
11
Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPA register and the counter is decrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxB output low.
10
Set: force EPWMxB output high.
11
Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.
Action when the counter equals the active CMPA register and the counter is incrementing.
00
Do nothing (action disabled)
01
Clear: force EPWMxB output low.
10
Set: force EPWMxB output high.
11
Toggle EPWMxB output: low output signal will be forced high, and a high signal will be forced low.
Copyright © 2012–2019, Texas Instruments Incorporated
11
10
CBD
R/W-0
3
2
PRD
R/W-0
SPRUH22I – April 2012 – Revised November 2019
Submit Documentation Feedback
www.ti.com
9
8
CBU
R/W-0
1
0
ZRO
R/W-0

Advertisement

Table of Contents
loading

Table of Contents