Error Status Clear Register (Err_Status_Clr); Error Counter Register (Err_Cnt); Error Threshold Register (Err_Threshold); Error Status Clear Register (Err_Status_Clr) Field Descriptions - Texas Instruments Concerto F28M35 Series Technical Reference Manual

Table of Contents

Advertisement

www.ti.com
5.4.4.6

Error Status Clear Register (ERR_STATUS_CLR)

31
15
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-128. Error Status Clear Register (ERR_STATUS_CLR) Field Descriptions
Bit
Field
31-3
Reserved
2
UNC_ERR_CLR
1
FAIL_1_CLR
0
FAIL_0_CLR
5.4.4.7

Error Counter Register (ERR_CNT)

31
Reserved
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 5-129. Error Counter Register (ERR_CNT) Field Descriptions
Bit
Field
31-16
Reserved
15-0
ERR_CNT
5.4.4.8

Error Threshold Register (ERR_THRESHOLD)

31
Reserved
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
SPRUH22I – April 2012 – Revised November 2019
Submit Documentation Feedback
Figure 5-124. Error Status Clear Register (ERR_STATUS_CLR)
Reserved
R-0
Value
Description
Reserved
Uncorrectable error clear. Writing a 1 to this bit will clear the UNC_ERR bit of ERR_STATUS
register.
Fail on 1 clear. Writing a 1 to this bit will clear the FAIL_1 bit of ERR_STATUS register. Writes of 0
have no effect.
Fail on 0 clear. Writing a 1 to this bit will clear the FAIL_0 bit of ERR_STATUS register. Writes of 0
have no effect.
Figure 5-125. Error Counter Register (ERR_CNT)
R
Value
Description
Reserved
Single bit error count. This counter increments with every single bit ECC error occurrence. Upon
reaching the threshold value counter stops counting on single bit errors. ERR_CNT can be cleared
(irrespective of whether threshold is met or not) using "Single Err Int Clear" bit. This is applicable for
ECC logic test mode and normal operational mode. In ECC logic test mode, ERR_CNT will keep
incrementing for every cycle after a single bit error occurrence. So, in order to clear ERR_CNT in
ECC logic test mode, ECC logic test mode has to be disabled prior to clearing the ERR_CNT using
"Single Err Int Clear" bit.
Figure 5-126. Error Threshold Register (ERR_THRESHOLD)
R
Copyright © 2012–2019, Texas Instruments Incorporated
Reserved
R-0
3
2
UNC_ERR_CL
R
R/W0-1
16 15
16 15
Flash Registers
1
FAIL_1_CLR
FAIL_0_CLR
R/W0-1
R/W0-1
ERR_CNT
R/W-0
THRESHOLD
R/W-0
Internal Memory
16
0
0
0
531