asieps_tobira_IM_US.book 9 ページ 2012年1月17日 火曜日 午後3時48分
B: ELECTRICAL SPECIFICATION
8
16
Item
Battery power supply
Ignition power supply
Ignition power supply
Inhibitor switch
("P" range)
Stop light switch
"P" range switch
Shift lock solenoid signal
Key warning switch signal
Key lock solenoid signal
Ground
Ground
AT Shift Lock Control System
B280
SIDE
7
6
5
4
3
2
1
15
14
13
12
11
10
9
To connector No.
Terminal No.
B280
2
B281
19
B281
10
B281
5
B281
9
B281
6
B280
9
B281
20
B280
3
B280
4
B280
13
CS-9
B281
SIDE
10
9
8
7
6
5
20
19
18
17
16
15
14
Input/Output signal
Measured value and measuring conditions
9 — 16 V
10 — 15 V when ignition switch is at ON or START.
10 — 15 V when ignition switch is at ACC.
0 V when select lever is in "P" range.
9 — 16 V when select lever is in other positions than "P" range.
9 — 16 V when stop light switch is ON.
0 V when stop light switch is OFF.
0 V when select lever is in "P" range.
9 — 16 V when select lever is in other positions than "P" range.
8.5 — 16 V when shift lock is released.
0 V when shift lock is operating.
9 — 16 V when key is inserted.
0 V when key is removed.
7.5 — 16 V when ignition switch is turned ON, with select lever in
"P" range and brake switch ON.
0 V at other conditions than above.
—
—
CONTROL SYSTEMS
4
3
2
1
13
12
11
CS-00011