6) Open/close the throttle valve, and check for
changes in duty ratio using the Subaru Select Mon-
itor.
Standard line pressure
Line pres-
Range
sure duty
position
ratio (%)
2
25 — 35
R
15 — 25
D
35 — 43
Line Pressure Test
Line pressure
Throttle
2
kPa (kgf/cm
,
valve angle
psi)
1,000 — 1,300
100
(10.2 — 13.3,
(Full open)
145 — 189)
1,500 — 1,850
100
(15.3 — 18.9,
(Full open)
218 — 268)
500 — 800
0
(5.1 — 8.2,
(Fully closed)
73 — 116)