390
C
4: L
L
P
HAPTER
INK
AYER
ROTOCOL
View
Interface view
Parameter
seconds: Delay time of resetting request (indication) timer in seconds, and its value
ranges from 0 to 1000. By default, the delay time on a DTE reset timer is 180
seconds; that on a DCE reset timer is 60 seconds.
Description
Using the x25 timer tx2 command, you can set resetting request (indication)
transmission timer delay for DTE (or DCE). Using the undo x25 timer tx2
command, you can restore its default value.
According to X.25, a timer should be started when a DTE sends a reset request (or
a DCE sends a reset indication). If no peer acknowledgement is received after this
timer is timeout, the sending end will take some measures to guarantee the
normal proceeding of the local procedure. This parameter specifies the delay time
of this timer before the timeout.
For the related commands, see x25 timer tx0, x25 timer tx1, and x25 timer tx3.
Example
Set the reset timer delay on the X.25 interface Serial0/0/0 to 120 seconds.
[3Com-Serial0/0/0] x25 tx2 120
x25 timer tx3
Syntax
x25 timer tx3 seconds
undo x25 timer tx3
View
Interface view
Parameter
seconds: Delay time of clearing request (indication) transmission timer in seconds,
and its value ranges from 0 to 1000. By default, the delay time on a DTE clearing
timer is 180 seconds; that on a DCE clearing timer is 60 seconds.
Description
Using the x25 timer tx3 command, you can set clearing request (indication)
transmission timer delay for DTE (or DCE). Using the undo x25 timer tx3
command, you can restore its default value.
According to X.25, a timer should be started when a DTE sends a clear request (or
a DCE sends a clear indication). If no peer acknowledgement is received after this
timer is timeout, the sending end will take some measures to guarantee the